Wire Gauge Calculator
Pick an American Wire Gauge size to see its diameter in millimeters and inches, its cross-section and its resistance in milliohms a meter. Or switch to Voltage drop, enter the length of the run, the current and the supply voltage, and see how many volts are lost in the wire, the voltage left at the load and the power wasted as heat, then find the thinnest gauge that keeps the drop within a percent you choose. Everything runs in your browser.
The diameter of a gauge follows the American Wire Gauge formula, d = 0.005 inch x 92 to the power of (36 - n) / 39, where n is the gauge number and 0000, 000, 00 and 0 count as -3, -2, -1 and 0. A lower number is a thicker wire, and every 6 gauges the diameter about doubles. The resistance is that of annealed copper at 20 C, 1 / 58,000,000 ohm meter, divided by the cross-section, which gives 3.277 milliohms a meter for AWG 10. All 44 sizes from 0000 to 40 match the table in Wikipedia's article on the American wire gauge. The voltage drop is the current times the resistance of the wire, counting the way out and the way back for a two-wire circuit. This tool does not say how much current a wire may carry: that depends on the insulation, the temperature, how the wire is run and local electrical rules, so check them or ask an electrician. Everything runs in your browser.
Related Tools
[5 suggestions]Ohm's Law Calculator: Voltage, Current, Resistance and Power
Enter any two of voltage, current, resistance and power to get the other two with Ohm's law, and add resistors in series or in parallel.
Student ToolsVoltage Divider Calculator: Output Voltage and Resistor Values
Find the output of a resistor voltage divider, with the effect of a load, or find the second resistor for the output you want, with the closest standard value.
Student ToolsLED Resistor Calculator: Series Resistor for an LED or Several LEDs
Find the series resistor for an LED from the supply voltage, the LED forward voltage and the current, with the standard value, the real current and the heat.
Student ToolsEV Charging Calculator: Time, Energy, Cost and Range Added
Work out how long an electric car takes to charge, the energy from the wall, the cost and the distance added, from the battery size and the charger power.
Math & MoneyElectricity Cost Calculator: What an Appliance Costs to Run
Calculate the kWh and the cost of running any appliance per hour, day, week, month and year from its watts, the hours of use and the price of a kWh.
Math & MoneyAbout the Wire Gauge Calculator
The diameter of a gauge follows the standard formula d = 0.005 inch x 92 to the power of (36 - n) / 39, where n is the gauge number and 0000, 000, 00 and 0 count as -3, -2, -1 and 0. A lower number is a thicker wire, and every 6 gauges the diameter about doubles. AWG 10 is 2.588 mm across with a cross-section of 5.26 square millimeters, and AWG 12 is 2.053 mm and 3.31 square millimeters. The resistance is that of annealed copper at 20 degrees Celsius, 1 over 58,000,000 ohm meter, divided by the cross-section, which gives 3.277 milliohms a meter for AWG 10 and 5.211 for AWG 12. All 44 sizes from 0000 to 40 match the table in Wikipedia's article on the American wire gauge. The voltage drop is the current times the resistance of the wire, and a two-wire circuit counts the way out and the way back. For AWG 12 over 20 meters at 15 amperes on 120 volts the wire is 0.208 ohm, so the drop is 3.13 volts, or 2.61 percent of the supply, and 47 watts are lost as heat. The tool does not say how much current a wire may safely carry, because that depends on the insulation, the temperature, how the wire is run and local electrical rules, so check them or ask an electrician.
What does AWG mean?▾
American Wire Gauge, a standard of wire sizes in which a lower number is a thicker wire. AWG 10 is 2.588 mm across and AWG 12 is 2.053 mm. Every 6 gauges the diameter about doubles.
How do I calculate voltage drop in a wire?▾
Multiply the current by the resistance of the wire, counting the way out and the way back for a two-wire circuit. AWG 12 over 20 m at 15 A has 0.208 ohm and drops 3.13 V, or 2.61 percent of 120 V.
How do I choose a wire gauge for a long run?▾
Enter the length, current and supply voltage, set the drop you can accept, such as 3 percent, and the tool gives the thinnest gauge that stays within it. Long runs and low voltages need thicker wire.
Does the tool tell me how much current a wire can carry?▾
No. It only works out the voltage drop. The safe current depends on the insulation, temperature, how the wire is run and local rules, so check those or ask an electrician.
Is my data uploaded?▾
No. The sizes and drops are worked out in your browser and nothing you enter is sent anywhere.